Mengchuan Instrument Co,Ltd.

We have excellent and experienced foreign trade team and other teams to provide you with the best and professional services. Our products are sold all over the world as best-selling products and high

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Differential Pressure Gauge /

Original And New FLUKE 110 True RMS Digital Multimeter 600V FLUKE-110/CN In Stock Weith Best Price

Contact Now
Mengchuan Instrument Co,Ltd.
Visit Website
City:wenzhou
Province/State:zhejiang
Country/Region:china
Contact Person:MissYANG
Contact Now

Original And New FLUKE 110 True RMS Digital Multimeter 600V FLUKE-110/CN In Stock Weith Best Price

Ask Latest Price
Video Channel
Brand Name :FLUKE
Model Number :FLUKE-110/CN
Certification :-
Place of Origin :China
MOQ :1
Price :USD105/PC
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :100000
Delivery Time :1WEEK
Packaging Details :Carton
Measuring Voltage Range :600v
Single package size :10X10X10 cm
Single gross weight :0.500 kg
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product overview: Fluke 110 True-rms Digital Multimeter

Compact true-rms meter for accurate electrical installation and troubleshooting

The Fluke 110 is a versatile multimeter for electrical measurements and troubleshooting. Trusted by residential and commercial electricians for troubleshooting and maintenance. The 110 is for professional use, where true-rms accuracy is needed.

Key product capabilities

  • True-rms ac voltage for accurate measurements on non-linear signals
  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated
  • Specifications: Fluke 110 True-rms Digital Multimeter

    Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] )

    General specifications
    Maximum voltage (between any terminal and earth ground) 600V
    Safety IEC 61010-1, Pollution degree 2
    IEC 61010-2-033, CAT III 600 V
    Display Digital: 6,000 counts, updates 4/sec
    Bar graph 33 segments, updates 32/sec
    Temperature
    Operating
    Storage

    -10 °C to + 50 °C
    -40 °C to + 60 °C
    Battery 9 volt Alkaline, IEC 6LR61
    Battery life 400 hours typical, without backlight
    Accuracy
    Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
    DC millivolts 600.0 mV 0.1 mV 0.5 % + 2
    DC volts 6.000 V
    60.00 V
    600.0 V
    0.001 V
    0.01 V
    0.1 V
    0.5 % + 2
    Accuracy
    Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
    AC millivolts1 true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz)
    2.0 % + 3 (500 Hz to 1 kHz)
    AC volts1 true-rms 6.000 V
    60.00 V
    600.0 V
    0.001 V
    0.01 V
    0.1 V
    1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
    Continuity 600 Ω 1 Ω Beeper on < 20 Ω, off> 250 Ω; detects opens or shorts of 500 μs or longer.
    Ohms 600.0 Ω 0.1 Ω 0.9 % + 2
    6.000 kΩ
    60.00 kΩ
    600.0 kΩ
    6.000 MΩ
    0.001 kΩ
    0.01 kΩ
    0.1 kΩ
    0.001 MΩ
    0.9 % + 1
    40.00 MΩ 0.01 MΩ 5 % + 2
    1All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled.
Inquiry Cart 0