The FLEXA™ series analyzers are modular-designed analyzers used for continuous online measurements in industrial installations. They offer single or dual sensor measurement, making them the most flexible 2-wire analyzer available.
With the FLXA202, there is no need for multiple analyzers, since it is easily scalable at the site location by swapping the internal measurement module to what is needed, giving you more flexibility and optimizing your OPEX.
Through the installation of up to two sensors, FLXA202 realizes interruption-free measurement even during maintenance. For dual sensor measurement, the sensor modules must be the same parameter – pH/ORP and pH/ORP, SC and SC, and DO and DO. Dual sensor measurement offers additional functionalities including a variety of calculated data from the two measuring parameters, as well as, the option to program the analyzer as a redundant system.
With the FLXA202, one analyzer can accept any of four types of measurements: pH/ORP, Contacting Conductivity (SC), Inductive Conductivity (ISC) and Dissolved Oxygen (DO)Sensors with self-diagnostics capabilities. Additional functions include:
The FLEXA™ series analyzer provides improved operability with intuitive touchscreen operation, featuring a clear display and user-friendly indication with 12 languages. A quick setup menu for immediate measurement and a display of sensor status and estimated maintenance time improve efficiency. The interactive screen is housed in a robust aluminum die-cast housing (FLXA202).
The FLEXA™ series analyzer features a modular design with replaceable sensor modules, enabling the construction of a variety of systems. Users can opt to do without a display and can also select the case material (plastic or stainless steel).
Through the installation of up to two sensors, FLXA202 realizes interruption-free measurement even during maintenance. For dual sensor measurement, the sensor modules must be the same parameter – pH/ORP and pH/ORP, SC and SC, and DO and DO. Dual sensor measurement offers additional functionalities including a variety of calculated data from the two measuring parameters, as well as, the option to program the analyzer as a redundant system.
With the FLXA202, one analyzer can accept any of four types of measurements: pH/ORP, Contacting Conductivity (SC), Inductive Conductivity (ISC) and Dissolved Oxygen (DO)Sensors with self-diagnostics capabilities. Additional functions include:
The FLEXA™ series analyzer provides improved operability with intuitive touchscreen operation, featuring a clear display and user-friendly indication with 12 languages. A quick setup menu for immediate measurement and a display of sensor status and estimated maintenance time improve efficiency. The interactive screen is housed in a robust aluminum die-cast housing (FLXA202).
The FLEXA™ series analyzer features a modular design with replaceable sensor modules, enabling the construction of a variety of systems. Users can opt to do without a display and can also select the case material (plastic or stainless steel).
Input Specification | Two or four electrodes measurement with square wave excitation, using max 60m (200ft) cable (WU40/WF10) and cell constants from 0.005 to 50.0 cm-1 | |
---|---|---|
Display range | Conductivity | min. 0.01 µS/cm, max. 2000 mS/cm (max 90% zero suppression) |
Resistivity | min. 0.001 kΩ x cm, max. 1000 MΩ x cm (max 90% zero suppression) | |
Temperature | min. span 25 ºC, max. span 270 ºC | |
Performance (Accuracy)(The specifications are expressed with simulated inputs.) | Conductivity | 2 µS x K cm-1 to 200 mS x K cm-1: Accuracy: ±0.5%F.S. 1 µS x K cm-1 to 2 µS x K cm-1: Accuracy: ±1%F.S. |
Resistivity | 0.005kΩ / K cm-1 to 0.5MΩ /K cm-1: Accuracy: ±0.5%F.S. 0.5MΩ / K cm-1 to 1MΩ /K cm-1: Accuracy: ±1%F.S. | |
Temperature | with Pt1000, Pb36, Ni100: Accuracy: ±0.3 ºC with Pt100, NTC 8k55: Accuracy: ±0.4 ºC | |
Temperature compensation | NaCl table: ±1 % Matrix: ±3 % | |
Temperature | 90 % (< 2 decades) in 7 seconds |